DIAMETER TOLERANCE 
		  Outside Diameter: De
		  Inside Diameter: Di
		  
            
            
            
            
            
            
              | De or Di | 
                Permissible deviation De                        Di                                   Concentricity | 
            
              |             MM | MM | MM | MM | 
            
              | 1 | Over 3 to 6 | 0/-0.12 | +0.12/0 | 0.15 | 
            
              | 2 | Over 6 to 10 | 0/-0.15 | +0.15/0 | 0.18 | 
            
              | 3 | Over 10 to 18 | 0/-0.18 | +0.18/0 | 0.22 | 
            
              | 4 | Over 18 to 30 | 0/-0.21 | +0.21/0 | 0.26 | 
            
              | 5 | Over 30 to 50 | 0/-0.25 | +0.25 | 0.32 | 
            
              | 6 | Over 50 to 80 | 0/-0.30  | +0.30/0 | 0.60 | 
            
              | 7 | Over 80 to 120 | 0/-0.35 | +0.35/0 | 0.70 | 
            
              | 8 | Over 120 to 180 | 0/-0.40 | +0.40/0 | 0.80 | 
            
              | 9 | Over 180 to 250 | 0/-0.46 | +0.46/0 | 0.92 | 
            
              | 10 | Over 250 to 315 | 0/-0.52 | +0.52/0 | 1.04 | 
            
              | 11 | Over 315 to 400 | 0/-0.57 | +0.57/0 | 1.14 | 
            
              | 12 | Over 400 to 500 | 0/-0.63 | +0.63/0 | 1.26 | 
          
		  1) In reference to Outside Diameter De 
		   
		  THICKNESS TOLERANCE (t) 
		  
		    
		    
		      |   |   t or t’ MM | Tolerance for t     MM | 
		    
		      | Group 1 |  0.2 to 0.6>0.6 to <1.25
 | +0.02 / -0.06 +0.03 / -0.09
 | 
		    
		      | Group 2 |  1.25 to 3.8>3.8 to 6.0
 | +0.04 / -0.12 +0.05 / -0.15
 | 
		    
		      | Group 3 | >6.0 to 14.0 | +0.10 / -0.10 | 
		    
		  FREE OVER-ALL HEIGHT (lo) TOLERANCE 
		  
		    
		    
		      |   | t [MM] | Tolerance for L0 | 
		    
		      | Group 1 | <1.25 | +0.10 / -0.05 | 
		    
		      | Group 2 | 1.25 to 2.0 >2.0 to 3.0
 >3.0 to 6.0
 | +0.15 / -0.08 +0.20 / -0.10
 +0.30 / -0.15
 | 
		    
		      | Group 3 | >6.0 to 14.0 | +0.30 / -0.30 | 
		    
		   
		  SPRING FORCE TOLERANCE 
		  The static load (F) of a single  
		  disc shall be determined for  
		  a disc in the loaded state  
		  using a suitable lubricant. The  
		  pressure plates between which  
		  the disc is compressed must be  
		  hardened ground and polished. 
		   
		  The following deviations apply for normal applications: 
		  
		    
		    
		      |   | t[MM] | Tolerances for F at the test length lp=lo -0.75 h o
 | 
		    
		      | Group 1 | <1.25 | +25% / -7.5% | 
		    
		      | Group 2 |  1.25 to 3.0 >3.0 to 6.0
 |  +15% / -7.5% +10% / -5%
 | 
		    
		      | Group 3 |  >6.0 to 14.0 | +5% / -5% |